Operating Instructions & Parts Manual RMC-FA300DGD
Dyna-Glo
TM
Delux
Propane Construction Heater
PROFESSIONAL GRADE
Description
Dyna-Glo
TM
Delux Model RMC-FA300DGD heaters are 300,000 BTU/Hr construction
heaters. This heater uses propane gas for combustion, and electricity to run the
fan. It is primarily intended for temporary heating of well-ventilated buildings
under construction, alteration or repair. This heater should be utilized in sheltered,
well-ventilated areas, but never in occupied dwellings.
CSA 2.14b-2009, ANS Z83.7b-2009 Construction Heater
C US
C US
Figure 1 - Model RMC-FA300DGD
Output Rating Maximum Fuel Regulator
Model BTU/Hr Fuel Consumption Ignition Outlet Pressure
RMC-FA300DGD 300,000 Propane Vapor Only 13.9 Lbs/Hr Direct Spark, Interrupted 7-10 PSIG
Hot Air Output Minimum Supply Maximum Supply Size Weight
Model Approx. (CFM) Motor Pressure to Regulator Pressure to Regulator L x W x H (Inches) (pounds)
RMC-FA300DGD 1800 0.085 HP 25 PSIG (For purposes Max Bottle Pressure 33.7 x 12.6 x 18.5 33.9 (Heater)
1,720 RPM of input adjustment) 42 (Shipping)
Table of Contents Page
Description .......................1
Specifications......................1
Unpacking ....................... 1
General Safety Information ........1-3
Theory of Operation................3
Installation......................3-4
Ventilation........................4
Operation ......................4-5
Maintenance ....................5-6
Storage ..........................6
Wiring Diagram....................6
Repair Parts Illustration
and Parts List ....................7-8
Troubleshooting Chart ..............9
Warranty ........................10
Unpacking
1. Unpack all materials used to protect
the heater inside of carton. Retain
plastic caps attached to exposed
fittings for use during storage.
2. Remove heater, accessories and all
hardware from carton.
3. Inspect all items for damage that may
have occurred during shipment.
General Safety Information
Make certain you read and understand
all warnings. Keep this instruction
manual for future reference, and use it
as a guide to safe and proper operation
of the heater.
Various precautions appear throughout
this manual. Please review and pay
close attention to them. Below is an
explanation of the various levels of
caution required while operation this
heater.
DANGER
Indicates an
im minen tly
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
WARNING
Indicates a poten-
tially hazardous
situation which, if not avoided, COULD
result in death or serious injury.
CAUTION
Indicates a poten-
tially hazardous
situa tion which, if not avoided, MAY
result in minor or moderate injury.
IMPORTANT: Every possible situation
that may involve a hazard cannot
be anticipated. The warnings in this
manual and on the heater itself
cannot be all inclusive. If an operating
technique or procedure that is not
specifically recom mend ed is used, you
must assure that it is safe for you and
anyone else within the heated space.
You must be sure that the heater will
not be damaged or made unsafe by
your handling of the maintenance or
operation of the heater.
Consumer: Retain this manual for future
reference.
Model Electrical Input Amperage
RMC-FA300DGD 120 V, 60 Hz 0.65
Electrical Specifications
General Specifications
Vue de la page 0
1 2 3 4 5 6 ... 10 11

Résumé du contenu

Page 1 - Propane Construction Heater

www.ghpgroupinc.comRev. 2012-06-07Printed in ChinaOperating Instructions & Parts Manual RMC-FA300DGDDyna-GloTM DeluxPropane Construction HeaterPR

Page 2

10RMC-FA300DGDDyna-GloTM Delux Operating Instructions and Parts ManualLIMITED WARRANTY:This limited warranty is extended to the original retail purcha

Page 3 - Models RMC-FA300DGD

WARRANTY REGISTRATIONIMPORTANT: We urge you to fill out your warranty registration card within fourteen (14)days of date of purchase. You can also reg

Page 4 - & Dyna-Glo

2Dyna-GloTM Delux Operating Instructions and Parts ManualFor Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST

Page 5 - Model RMC-FA300DGD

3Models RMC-FA300DGDFor Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST www.ghpgroupinc.comDyna-GloTM Delux

Page 6

InstallationReview and under-stand all of thewarnings in the Safety InformationSection on pages 1–3. They are requiredto operate this heater safely. F

Page 7 - RMC-FA300PF/DG/DGD

5Model RMC-FA300DGDFor Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST www.ghpgroupinc.comDyna-GloTM Delux O

Page 8

6ProFitterTM& Dyna-GloTMPropane Construction HeaterRMC-FA300PF/DG/DGDProFitterTM& Dyna-GloTMOperating Instructions and Parts ManualMaintenance

Page 9

8RMC-FA300PF/DG/DGDFor Repair Parts, call 1-877-447-476824 hours a day – 365 days a yearPlease provide following information:-Model number-Serial numb

Page 10 - Warranty

Model RMC-FA300DGD8RMC-FA300DGDFor Technical Support or Troubleshooting, Call: 1-877-447-4768, 8:30 am - 4:30 pm CST www.ghpgroupinc.comDyna-G

Page 11 - WARRANTY REGISTRATION

WARRANTY:SERVICE AND LIMITED WARRANTYGHP Group, Inc., warrants this product to be free from defects in materials and components for one (1) year from